Research Article

Effects of freezing, liquid nitrogen, and formaldehyde preservation on rat achilles tendon biomechanics

Volume 60 · Issue 6 · October 2026 Publish Date: October 30, 2026
Full Text PDF
DOI
Lu Zhang ORCID
Department of Ultrasonics, Wanghailou Community Health Center, Tianjin, China
Jie Wang ORCID
Department of Joint Surgery, Tianjin Hospital, Tianjin University, Tianjin, China
Wenbo Hou ORCID
Medical School of Tianjin University, Tianjin, China
Lei Wang ORCID
Department of Joint Surgery, Tianjin Hospital, Tianjin University, Tianjin, China
Zhang, L., Wang, J., Hou, W., & Wang, L. (2026). Effects of freezing, liquid nitrogen, and formaldehyde preservation on rat achilles tendon biomechanics. Acta Orthopaedica Et Traumatologica Turcica, 60(6). https://doi.org/10.5152/j.aott.2026.25749
Full Text Full text PDF

Abstract

Objective: This study aimed to evaluate the effects of different preservation methods, including −20°C freezing, −80°C freezing, liquid nitrogen, and 10% formaldehyde preservation, on the biomechanical properties of rat Achilles tendons.

Methods: This experimental biomechanical study included Achilles tendons obtained from 25 male Sprague–Dawley rats (age, 3 months; weight, 220–280 g). The rats were randomly allocated to five groups (n = 5 each): fresh, −20°C freezing, −80°C freezing, liquid nitrogen preservation, and 10% formaldehyde preservation. Specimens in the preservation groups were stored for 1 week before biomechanical testing. Following preconditioning, the tendons were subjected to axial tensile loading at 3 mm/min until failure. Cross-sectional area, maximum elongation, maximum strain, maximum stress, maximum load, and stiffness were evaluated.

Results: Initial tendon length did not differ among the 5 groups (P = .92). Maximum load was comparable between the fresh (48.78 ± 2.35 N), −20°C (50.28 ± 2.57 N), and −80°C (48.95 ± 3.21 N) groups, whereas it was significantly lower in the liquid nitrogen (34.21 ± 2.98 N) and 10% formaldehyde (23.55 ± 2.39 N) groups (P < .05). Stiffness was significantly higher in the −20°C (32.99 ± 2.37 N/mm) and −80°C (30.74 ± 1.63 N/mm) groups than in the fresh (25.80 ± 1.11 N/mm), liquid nitrogen (23.21 ± 1.27 N/mm), and 10% formaldehyde (19.66 ± 1.36 N/mm) groups (P < .05). The 10% formaldehyde group also showed significantly lower maximum elongation, maximum strain, and maximum stress than the cryopreservation groups (P < .05).

Conclusion: Preservation at −20°C and −80°C maintained maximum tendon load at levels comparable to fresh tendons but resulted in increased stiffness. Liquid nitrogen and 10% formaldehyde preservation were associated with lower maximum load, with the most pronounced alterations observed after formaldehyde preservation. These findings indicate that the choice of preservation method should be considered when interpreting biomechanical tendon studies, as different preservation methods may affect individual biomechanical parameters differently.

 

Cite this article as: Zhang L, Wang J, Hou W, Wang L. Effects of freezing, liquid nitrogen, and formaldehyde preservation on rat Achilles tendon biomechanics. Acta Orthop Traumatol Turc., 2026; 60(6), 0749, doi:10.5152/j.aott.2026.25749.

Similar Articles

Article Info
Published In
Journal Acta Orthopaedica et Traumatologica Turcica
Volume / Issue Volume 60 · Issue 6 · October 2026
History
Published Online October 30, 2026
Copyright
Affiliations
1
Lu Zhang ORCID
Department of Ultrasonics, Wanghailou Community Health Center, Tianjin, China
2
Jie Wang ORCID
Department of Joint Surgery, Tianjin Hospital, Tianjin University, Tianjin, China
3
Wenbo Hou ORCID
Medical School of Tianjin University, Tianjin, China
4
Lei Wang ORCID
Department of Joint Surgery, Tianjin Hospital, Tianjin University, Tianjin, China
Cite this Article
Zhang, L., Wang, J., Hou, W., & Wang, L. (2026). Effects of freezing, liquid nitrogen, and formaldehyde preservation on rat achilles tendon biomechanics. Acta Orthopaedica Et Traumatologica Turcica, 60(6). https://doi.org/10.5152/j.aott.2026.25749
Outlines