Research Paper

The effect of onlay cortical fibula strut grafts on biomechanical features of Vancouver type B1 periprosthetic femoral fractures

Volume 56 · Issue 3 · January 2022 Publish Date: May 1, 2022
Full Text PDF
DOI
Orkhan Aliyev
Department of Orthopedics and Traumatology, Bezmialem Vakıf University, School of Medicine, İstanbul, Turkey
Tunay Erden
Department of Orthopedics and Traumatology, Bezmialem Vakıf University, School of Medicine, İstanbul, Turkey
Kerim Sarıyılmaz
Department of Orthopedics and Traumatology, Acıbadem University, School of Medicine, İstanbul, Turkey
Ergün Bozdağ
Laboratory of Biomechanics and Strength of Materials, İstanbul Technical University, School of Mechanical Engineering, İstanbul, Turkey
Emin Sünbüloğlu
Laboratory of Biomechanics and Strength of Materials, İstanbul Technical University, School of Mechanical Engineering, İstanbul, Turkey
Fatih Yıldız
Department of Orthopedics and Traumatology, Bezmialem Vakıf University, School of Medicine, İstanbul, Turkey
İbrahim Tuncay
Department of Orthopedics and Traumatology, Bezmialem Vakıf University, School of Medicine, İstanbul, Turkey
Aliyev, O., Erden, T., Sarıyılmaz, K., Bozdağ, E., Sünbüloğlu, E., Yıldız, F., & Tuncay, İbrahim. (2022). The effect of onlay cortical fibula strut grafts on biomechanical features of Vancouver type B1 periprosthetic femoral fractures. Acta Orthopaedica Et Traumatologica Turcica, 56(3), 166–172. https://doi.org/10.5152/j.aott.2022.21287
Full Text Full Text PDF

Abstract

Objective: This study aimed to investigate biomechanically the effects of onlay fibula grafts on Vancouver Type B1 Periprosthetic Femoral Fractures (PPFs).

Methods: Vancouver Type B1 PFF models were created in 25 fourth-generation synthetic femurs and fixed with locking plates using bicortical, unicortical screws, and cables. While no graft was used in group 1, onlay fibula grafts were placed anteriorly in group 2 and medially in group 3. In group 4, the cortical strut allograft was placed on the medial femoral cortex, and a locking compression plate (LCP) was applied to the lateral femoral cortex. In group 5, the strut allograft was placed over the anterior cortex of the femur and fixed with the same technique as in group 4. All models were then subjected to rotational and axial cyclical stiffness tests and load to failure to measure and compare the mechanical strengths of the constructs.

Results: The mean stiffness values of group 4 with medial allograft, before and after cyclical loading, were higher than all other groups, under both rotational and axial forces. The mean stiffness values of fibula autografts (groups 2 and 3) were similar to that of anterior allografts (group 5) in each test except that the mean initial axial stiffness of group 5 was higher than group 2. Failure loads were also not different between the groups.

Conclusion: Although the rigidity of Vancouver type B1 periprosthetic femur fractures is highest if allografts are placed medially, fibula autografts can also provide similar fixation strengths to allografts if locking plates with unicortical and bicortical screws and cables are used.

Cite this article as: Aliyev O, Erden T, Sarıyılmaz K, et al. The effect of onlay cortical fibula strut grafts on biomechanical features of vancouver type B1 periprosthetic femoral fractures. Acta Orthop Traumatol Turc. 2022;56(3):166-172.

Similar Articles

Article Info
Published In
Journal Acta Orthopaedica et Traumatologica Turcica
Volume / Issue Volume 56 · Issue 3 · January 2022
Pages 166-172
History
Published Online May 1, 2022
Copyright
Affiliations
1
Orkhan Aliyev
Department of Orthopedics and Traumatology, Bezmialem Vakıf University, School of Medicine, İstanbul, Turkey
2
Tunay Erden
Department of Orthopedics and Traumatology, Bezmialem Vakıf University, School of Medicine, İstanbul, Turkey
3
Kerim Sarıyılmaz
Department of Orthopedics and Traumatology, Acıbadem University, School of Medicine, İstanbul, Turkey
4
Ergün Bozdağ
Laboratory of Biomechanics and Strength of Materials, İstanbul Technical University, School of Mechanical Engineering, İstanbul, Turkey
5
Emin Sünbüloğlu
Laboratory of Biomechanics and Strength of Materials, İstanbul Technical University, School of Mechanical Engineering, İstanbul, Turkey
6
Fatih Yıldız
Department of Orthopedics and Traumatology, Bezmialem Vakıf University, School of Medicine, İstanbul, Turkey
7
İbrahim Tuncay
Department of Orthopedics and Traumatology, Bezmialem Vakıf University, School of Medicine, İstanbul, Turkey
Cite this Article
Aliyev, O., Erden, T., Sarıyılmaz, K., Bozdağ, E., Sünbüloğlu, E., Yıldız, F., & Tuncay, İbrahim. (2022). The effect of onlay cortical fibula strut grafts on biomechanical features of Vancouver type B1 periprosthetic femoral fractures. Acta Orthopaedica Et Traumatologica Turcica, 56(3), 166–172. https://doi.org/10.5152/j.aott.2022.21287
Outlines