Acta Orthopaedica et Traumatologica Turcica

A rare complication after total knee replacement Suction drain leaved in joint space

AOTT 1998; 32: Supplement 424-425
Read: 731 Downloads: 563 Published: 19 April 2021
Abstract

Total knee arthroplasty is a choice of treatment that relief pain, correct deformity and improve functions for the patients who have knee arthrosis. Currently, this treatment modality had became more popular. To achieve these purposes, the number of this kind of operations had increased. That is why, complications about these procedures have became more visible. In one of our patients whom we had performed total knee arthroplasty, drain has broken out at its distal part when we pulled the drain at the second day postoperatively. In this case report, we want to present a rare complication and its treatment way.

Özet

Total diz protezi uygulaması artrozlu dizlerde ağrıyı azaltmak, deformiteyi düzeltmek, fonksiyonları iyileş-tirmek amacıyla yapılan bir tedavi yöntemidir. Son yıllarda protez uygulaması yapılan vaka sayısının artmasına paralel olarak bu uygulama ile ilgili komplikasyonlara daha sık rastlanmaktadır. Bu olgu sunumunda, primer gonartroz tanısı ile total diz protezi uygulaması yapılan bir hastamızda \"dren çekilirken dren ucunun eklem içinde kalması\" az görülen bir komplikasyon olması nedeniyle ilginç bulunarak sunulmuştur.

Files
ISSN 1017-995X EISSN 2589-1294